Detected Gas: | NH3, Ammonia | Measure Range: | 0-50ppm, 0-100ppm, 0-200ppm, 0-500ppm, 0-1000ppm, 0-2000ppm, 0-5000ppm, 0-100%VOL |
---|---|---|---|
Color: | Blue | Packing: | Paper Box |
Install Method: | Wall-mounted, Piping-type, Flow-type | Power: | 12-36Vdc |
Highlight: | gas measuring device,gas leak detector |
ATEX Approved High Sensitivity Single Gas Detector Toxic Monitor Nh3 Ammonia Gas Tester Fixed Gas Detector
Currently, most customers measure the ammonia gas concentration in livestock farm, chicken farm or refrigerant plant, wast treatment plant, etc. YuanTe's ammonia detector is accurate and reliable, fast response. We can provide different measure range/scale to meet demand of different kind of detected environment.
ATEX Approved High Sensitivity Single Gas Detector Toxic Monitor Nh3 Ammonia Gas Tester Fixed Gas Detector Characteristics:
1. Standard equipped with three-wire system 4-20mA analog output; relay output; RS485 output.
2. Unique infrared ray control function, which can non-contacted control the device.
3. Being compatible with all kinds of controlled alarms, PLC, DCS and other control system, can be remote monitored.
4. Alarm mode is sound and light, alarm point is settable.
5. Explosion-proof design, fast, reliable and stable.
6. Explosion-proof grade: Ex dⅡCT6
7. With self-calibration function, and three standard keys will be used to realize on-site maintenance.
8. Detachable probe/gas cell: It is very easy to calibrate and replace sensor
ATEX Approved High Sensitivity Single Gas Detector Toxic Monitor Nh3 Ammonia Gas Tester Fixed Gas Detector Funtions:
1. Monitor the NH3, Ammonia gas in environment or pipeline.
2. With self-calibration and zero calibration function, makes the detection more accurate and reliable.
3. With temperature compensation, this is able to realize gas concentration compensation under conditions of different temperatures.
4. Infrared ray controller can remote control alarm point settings, zero calibration, and address modification. (optional)
5. Can output one or two on-off signals, can drive ventilator or solenoid valve and other external devices. (optional)
6. Working Voltage:24V DC
7. Case: die-cast aluminum
ATEX Approved High Sensitivity Single Gas Detector Toxic Monitor Nh3 Ammonia Gas Tester Fixed Gas Detector Specification
Gas detected |
NH3, Ammonia |
||
Detection principle |
Electrochemistry, IR |
||
Install method |
Wall-mounted, piping type, flow-type (according to the detected environment) |
||
Measure range |
0-50ppm, 0-100ppm, 0-200ppm, 0-500ppm, 0-1000ppm, 0-2000ppm, 0-5000ppm, 0-100%VOL |
||
Resolution |
0.01ppm, 0.1ppm, 1ppm, 0.01%VOL |
||
Precision |
≤± 1% FS or ± 2-3% FS |
||
Signal output |
4-20mA, 0-5V, RS485, relay(optional) |
||
Response time |
≤10S |
Recovery time |
≤10S |
Repeatability |
≤±1% |
Linearity error |
≤±1% |
Zero shift |
≤±1%(FS/year) |
Display |
High-light nixie tube display |
Connection mode |
G1/2 external thread explosion-proof flexible pipe |
Unit |
ppm |
Temperature |
-20 to 50°C |
Humidity |
0-95%RH |
Explosion-proof |
Ex dⅡCT6 |
Degree of protection |
IP65 |
Alarm |
Sound, light |
Operating time |
24H |
Dimensions |
180*150*90mm |
Weight |
≤2kg |
FAQ
1. Do you offer guarantee for the products?
-- Yes, we offer one year guarantee for the products.
2. Can you produce according to customers' design?
--Yes,We are factory with our own R&D team.
Customized color and special function of gas detection tools.
Customized box.
Your other ideas about gas detection tools, we can help you design and put them into production.
Different language files. such as English, etc. according to customers requirement.
3. Is it OK to print my logo on the gas detector?
Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
4. How do you sure the quallty of products?
Our company owns the core technology ,all kinds of products hold qualification certificate.