Test Gas: | Hfc125 Gas R125 R134A R404A | Test Pinciple: | IR |
---|---|---|---|
Product Color: | Yellow | Sampling Type: | Pump |
Product Name: | Refrigerant Gas Leak Detector | Measure Range: | 0-2000ppm |
Highlight: | R125 Refrigerant Gas Leak Detector,R404A Gas Measuring Device,R134A Gas Leak Detector |
Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector
SKY2000 series gas detector is a kind of fast response and high accuracy gas measurement device. With internal sampling pump, fast sampling speed and high flow rate, ensuring the response time of the detector. Unique design, small size and easy to carry with. Special high intensity engineering plastics housing, suitable for different kinds of situation and environment. We dedicate to provide you the most reliable, accurate and the safest solution of gas detection.
Gas Detected | Hfc125 Gas R125 R134A R404A | ||
Detection principle | IR | ||
Sampling Method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. | ||
Measure Range | 0-2000ppm | ||
Resolution | 0.001ppm | ||
Precision | ≤± 2% F.S. | ||
Signal Output | High-speed data transmission by USB, available for data downloading and printing(optional function) | ||
Response Time | ≤10S | Recovery Time | ≤10S |
Repeatability | ≤±1% | Linearity error | ≤±1% |
Zero shift | ≤±1%(F.S/year) | Display | LCD dot matrix display |
Operating language | Chinese/English | Gas unit | Units are switchable |
Temperature | -40℃~70℃ | Humidity | 0-95%RH |
Explosion-Proof | ExiaⅡCT4 | Degree of protection | IP66 |
Alarm mode | Sound, light, vibration | Operating time | 100h(pump off) |
Dimensions | 205*75*32mm | Weight | 300g |
Product Advantegas
Attentions
● The air intake of the sensor must be kept clean. Blocking the sensor's air intake may result in readings that are lower than the actual gas concentration or even the gas concentration. It is strictly forbidden to use compressed air to clean the air inlet of the sensor to avoid damage to the sensor.
● Catalytic Principle Flammable Gas Sensor and Infrared Principle Sensor can only accurately monitor designated gases. It should be noted, however, that the catalytic principle flammable sensor is not specific to a particular gas and will be able to react to other flammable gases.
● If the instrument is subject to physical impact or high pollution, the calibration cycle needs to be shortened.
● The sensitivity of flammable gas sensors will be affected by high concentrations of sulfides, halogen compounds, silicon-containing compounds, and gases containing "mercury" and "lead", steam, and high temperature organic acid gases. Avoid using them in environments containing the above chemicals. The instrument, if necessary, must be tested and calibrated after use to avoid affecting the accuracy of the instrument.
● The instrument is strictly prohibited from being used in a high concentration of flammable gas for a long time to avoid damage to the flammable sensor. If it is necessary, the instrument should be tested and calibrated after use to avoid affecting the accuracy of the instrument. If the flammable sensor is damaged, it needs to be replaced with a new one.
FAQ
Q1. How can I get the sample to check your quality?
After price confirmation, you can require for samples to check our product’s quality.
Q2. What can I get the price?
We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please just call us we will regard your inquiry priority.
Q3. What is your term of delivery?
We accept EXW, DAP, FOB Shenzhen. You can choose the best convenient or cost effective way for you.
Q4. What about the lead time for the mass production?
Honestly, it depends on the order quantity and the season you place the order.