Test Gas: | Combustible Gas | Device Type: | Fixed |
---|---|---|---|
Sampling Type: | Diffusion | Principle: | Catalytic Combustion |
Application: | Gas Filling Station | Product Name: | Combustible Ex Gas Leak Detector |
Highlight: | RS485 Single Gas Detector,CT6 Single Gas Detector,IP65 Fixed Gas Detector |
Fixed Combustible Gas Detector Combustible Ex Gas Leak Detector for Gas Filling Station
Characteristics & Functions
1. Being compatible with all kinds of controlled alarms, PLC, DCS and other control system, can be remote monitored.
2. Explosion-proof design, fast, reliable and stable. Explosion-proof grade: Ex d II CT6
3. With self-calibration function, and three standard keys will be used to realize on-site maintenance.
4. Monitor the ammonia gas concentration in environment or pipeline and alarm.
5. Two-stage alarm with sound and light, alarm point is settable.
6. Infrared ray controller can remote control alarm point settings, zero calibration, and address modification.
7. Can output one or two on-off signals, can drive ventilator or solenoid valve and other external devices.
Gas Detected | Combustible Gas | ||
Detection principle | Catalytic Combustion | ||
Install methode | Wall-mounted, piping type, flow-type(according to the detected environment) | ||
Measure Range | 0-100%LEL | ||
Resolution | 0.01%LEL | ||
Precision | ≤± 3% F.S. | ||
Signal Output | 4-20MA, RS485, relay | ||
Response Time | ≤10S | Recovery Time | ≤10S |
Repeatability | ≤±1% | Linearity error | ≤±1% |
Zero shift | ≤±1%(F.S/year) | Display | High light nixie tube display |
Operating language |
G1/2 external thread explosion-proof flexible pipe |
Gas unit | ppm |
Temperature | -20ºC~50ºC | Humidity | 0-90%RH |
Explosion-Proof | Ex d II CT6 | Degree of protection | IP65 |
Alarm mode | Sound, light | Operating time | 24h |
Dimensions | 180*150*90mm | Weight | ≤1.6kg |
In order to use the gas detector correctly and prevent the gas detector from malfunctioning, please do not install it in the following locations:
1. Places directly affected by steam and oil fume;
2. Places with large air flow such as air inlets, ventilating fans, and room doors;
3. Places with a lot of water vapor and water droplets (relative humidity ≥95%RH);
4. Places where the temperature is below -40℃ or above 65℃;
5. Places with strong electromagnetic fields
Company Profile
Our company Shenzhen Yuante Co., Ltd is specializing in the production, research and development of gas detector for more than 10 years. We have ATEX, IECEx, CE and ISO certificate. Main product have SKY2000, SKY3000, SKY6000, SKY8000, YT-95H and YT-1200H. We have portable one and fixed one. Welcome to consult.
Installation