| Gas Detected: | Phosphine(PH3) | Measure Range: | 0-5, 10, 20, 100, 1000, 2000, 3000ppm |
|---|---|---|---|
| Detection Principle: | Electrochemical | Resolution: | 0.01ppm, 0.1ppm, 1ppm |
| Sampling Method: | Pump / Diffusion | Alarm Mode: | Sound, LED And Vibration Alarm |
| Protection Grade: | IP66, Can Effectively Waterproof And Dustproof | Operating Time: | 100 Hours(with Pump Off) |
| Weight: | 0.3 Kilogram | Temperature: | From -20℃ To 50℃ |
| Humidity: | Within 0 To 90%RH | ||
| Highlight: | Container Disinfection ph3 gas detector,Imported Sensor Portable Single Gas Detector,PH3 Portable Single Gas Detector |
||
| Parameter | Specification |
|---|---|
| Gas Detected | Phosphine (PH3) |
| Measure Range | 0-5, 10, 20, 100, 1000, 2000, 3000ppm |
| Detection Principle | Electrochemical |
| Instrument Lifespan | Sensors: 2-3 years, Instruments: ≥5 years |
| Linearity Error | ±2%FS |
| Response Time | T90<30S (25℃) |
| Sampling Method | Pumping Suction |
| Resolution | 1 |
| Signal Output (Optional) | High-speed USB data transmission |
| Operating Language | Chinese/English |
| Temperature Range | -20℃~50℃ |
| Explosion-Proof Rating | Ex ia II CT4 |
| Alarm Mode | Sound, Light, Vibration |
| Dimensions | 205×75×32mm |
| Recovery Time | ≤10S |
| Display | LCD Dot Matrix |
| Gas Unit | Switchable Units |
| Humidity Range | 0-90%RH |
| Protection Level | IP66 |
| Operating Time | 100h (pump off) |
| Weight | 300g |