Gas Detected: | Specified According To Application. | Measure Range:: | Specified According To Application. |
---|---|---|---|
Resolution:: | Specified According To Application. | Principle:: | Electrochemical Principle |
Accuracy:: | ≤±2-5%FS (depending On The Specific Sensor) | Response Time(T90):: | 15-30s(depending On The Specific Sensor) |
Unit:: | PPM, Mg/m3, %VOL | Display:: | Gas Name, Concentration Unit, Measured Value, Battery Power |
Alarm Mode:: | Sound, Light, Vibration Alarm, High And Low Alarm Values Can Be Set By Yourself | Alarm Type:: | Low Alarm, High Alarm, STEL, TWA, Low Battery Optional Calibration Due And Bump Test Due |
Power Supply Mode:: | 3.6V Dry Battery (non-rechargeable | Explosion-proof Grade:: | ExiaIICT4Ga |
Protection Class:: | IP68 | Executive Standards:: | GB 12358-2006, GB 3836.1-2010,GB 3836.4-2010, JJF1421-2013, JJF1363-2019, JJF1364-2012, JJG 365-2008, IEC 60079-0-2017, IEC 60079-11-2 |
Working Temperature:: | -20℃~55℃ | Working Humidity:: | 0-95%RH (non-condensing) |
Working Air Pressure:: | 86~106kpa | Dimensions:: | 90*60*33mm (length*width*thickness) |
Weight:: | 125g (With Clip) | ||
Highlight: | IECEX ATEX certified gas detector,IP68 single gas detector,compact 90x60x33mm gas detector |
MiniMeta is an IECEX/ATEX/EMC certified single-gas detector. It can detect hundreds of user-selected toxic gases, user friendly and easy for operation. The battery and sensor is replaceable to provide user a long-term protection. It is designed to offer a low long-term ownership cost of a gas monitoring system.
Parameter | Specification |
---|---|
Gas Detected | Specified according to application |
Detection Principle | Diffusion |
Measure range | Specified according to application |
Resolution | Specified according to application |
Accuracy | ≤±2-5%FS (depending on the specific sensor) |
Response time(T90) | 15-30s (depending on the specific sensor) |
(Detection) Principle | Electrochemical principle |
Unit | PPM, mg/m³, %VOL |
Display | Gas name, concentration unit, measured value, battery power |
Alarm mode | Sound, light, vibration alarm, high and low alarm values can be set by yourself |
Alarm type | Low alarm, high alarm, STEL, TWA, low battery optional calibration due and bump test due |
Power supply mode | 3.6V dry battery (non-rechargeable) |
Explosion-proof grade | ExiaIICT4Ga |
Protection class | IP68 |
Executive standards | GB 12358-2006, GB 3836.1-2010, GB 3836.4-2010, JJF1421-2013, JJF1363-2019, JJF1364-2012, JJG 365-2008, IEC 60079-0-2017, IEC 60079-11-2 |
Working temperature | -20℃~55℃ |
Working humidity | 0-95%RH (non-condensing) |
Working air pressure | 86~106kpa |
Dimensions | 90×60×33mm (length×width×thickness) |
Weight | 125g (With Clip) |