| Gas Type: | CL2, CLO2 | Working Method: | Diffusion Sampling |
|---|---|---|---|
| Response Time(T90): | ≤30 Seconds | Calibration Platform: | Optional Docking Station To Perform Daily Calibration And Bump Test |
| Battery: | Lithium Battery, 3.7V Rechargeable Battery | Wireless Transmission(Optional): | Bluetooth / Lora |
| Working Hours: | About 24 Hours | Charging Time: | Less Than 6 Hours |
| Certification: | ATEX, CN, IECEX | Protection Grade: | IP66/IP68 |
| Weight(with Internal Battery): | 240g | Data Record: | 1000 Sets |
| Events Record: | 100 Sets | ||
| Highlight: | IECEX Certificated Multi Gas Detector,Wireless Transmission Gas Analyzer,Minisize Gas Concentration Meter |
||
MicMeta is a multi-gas detector with IP66/IP68 protection. Under normal circumstances, MicMeta can detect 1-4 gases simultaneously. With two conventional range gases (CO and H2S), it can detect up to 5 gases at the same time.
MicMeta has obtained three explosion-proof certifications: IECEx, ATEX, and China Explosion-proof. The explosion-proof level is Ex ia IICT4 Ga/Ex ia I Ma, allowing use in both Zone 0 and Zone 1 hazardous areas.
Features include an LCD screen with Chinese/English language switching, gas unit conversion, two-level sound and light alarm with customizable alarm points, optional PC software for data download, and optional docking station for bump testing, calibration, configuration, and data recording.
Small size with light weight (240g), robust and durable construction withstands drops up to 1.5 meters. IP66/IP68 rating provides effective waterproof and dustproof protection.
Simple two-button operation for easy use and configuration.
Features a wide-angle visual alarm bar for increased visibility in various conditions.
Successfully passed EMC anti-static interference tests, ensuring reliable operation in diverse environments.
Comfortable, wear-resistant back clip that is lightweight for easy carrying during extended use.
| Sampling method | Diffusion suction |
| Gas type | CL2 AND CLO2 |
| Measure range | Customize, CL2 0-200PPM, CLO2 0-50PPM |
| Resolution | 0.1PPM, 1PPM |
| Response time | ≤60S (T90) |
| Precision | ≤±5%FS or ±10% (depends on the specific sensor) |
| Language | Chinese/English |
| Automatically test and calibrate after power-on | Including auto-test, calibration, auto-zero, maximum value (MAX), minimum value (MIN), STEL, TWA value |
| Unit | PPM and mg/m³ can be switched and displayed by one key, concentration value automatically converted by system |
| Display | Segment code LCD display |
| Calibration platform | Modification, function testing and calibration operations can be performed on DKM-MicMeta docking station (optional) |
| Data record | 1000 sets data records and 100 sets events records |
| Alarm | 95dB buzzer (@30cm), vibration alarm and flashing red bar, on-screen alarm status indication, alarm lock; Diagnostic alarms and battery undervoltage alarms, man down alarms, all sensor alarm value is settable |
| Battery | 3.7V rechargeable lithium battery, battery capacity 2300mA |
| Working hours | Standby time 18h, charging time <6h |
| Wireless transmission | Bluetooth transmission function (optional), Lora transmission function (optional) |
| Explosion-proof grade | IECEx: Ex ia IIC T4 Ga, Ex ia I Ma ATEX: II 1G Ex ia IIC T4 Ga, Ex ia I Ma (EU regulations): 2004/108/EC(EMC), 94/9/EC(ATEX), CE |
| Protection grade | IP66/IP68 |
| Working temperature | -20°C~55°C |
| Humidity | 0-95%RH (non-condensing) |
| Environmental pressure | 86~106Kpa |
| Size | 113*60*32mm (length * width * height) |
| Weight | 200g (with lithium battery) |
MicMeta can detect 1-5 gases simultaneously. The system supports detection of various gases including CL2 and CLO2 as specified.
As a professional gas detector manufacturer, we control the entire process from design-R&D-production-sales to ensure consistent product quality. We have more than 100 independent intellectual property patents in design and development.
In production, we have skilled technical workers and a complete industrial line, ensuring full control over production and quality throughout the process. Our company has rich overseas sales experience and a professional sales team, providing customers with 7*24h considerate service.
Our professional R&D department has been engaged in gas detection industry for about 25 years. They possess professional knowledge and rich experience, enabling them to provide customers with professional technical after-sales service.
We implement a strict quality management system with the principle of quality first as the core. This commitment has been recognized by authoritative organizations through ISO9001 and ISO14001 certifications, ensuring safe and environmentally friendly products.
Our products have obtained IECEx and ATEX explosion-proof certification, allowing use in hazardous areas such as mines, underground facilities, and oil plants. We are the first and currently the only manufacturer in China to obtain this certification.
Our core components, including ICs and sensors, use imported brands to improve product accuracy, stabilize service life, ensure detection accuracy, and protect customer safety.
Our complete product line and stable inventory enable fast delivery. Orders under 10 units typically ship within 3 days, while quantities over 100 units are delivered within half a month under normal circumstances.
A1: A gas detector is an instrument for detecting gas leakage concentration, including portable gas detectors, fixed gas detectors, and other types.
A2:
Combustible gases: Natural gas (methane), liquefied gas, coal gas, acetylene, pentane, alkynes, toluene, etc.
Toxic gases: Carbon monoxide, hydrogen sulfide, ammonia, chlorine, phosphine, sulfur dioxide, hydrogen chloride, chlorine dioxide and other toxic and harmful gases.
A3: ppm represents the volume concentration of the gas, meaning the volume of pollutants contained in one million volumes of air. For example, if the concentration of ammonia is 30ppm, it means that the volume of ammonia in one million volumes of air is 30.