logo
products

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

Basic Information
Place of Origin: China
Brand Name: Safegas
Certification: ATEX/EX
Model Number: SKY2000
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Carton
Delivery Time: 3 Working days
Payment Terms: T/T
Supply Ability: 100 Pieces/day
Detail Information
Gas Type: EX Detection Range: 0–100%LEL
Resolution: 1%LEL Data Logging: Yes
Suction Type: Pump-suction Response Time: ≤ 20 Seconds
Operating Language: Chinese / English Switchable Recovery Time: ≤ 10 Seconds
Degree Of Protection: IP66
Highlight:

0–100%LEL Combustible Gas Detector

,

1%LEL Resolution Multi Gas Detector

,

Data Logging USB Export Gas Detector


Product Description

SKY2000 Pump-Suction Combustible Gas Detector

0–100%LEL 1%LEL Resolution with Data Logging & USB Export

Product Overview – Compact, Fast, Reliable

The SKY2000 series is a portable pumped gas detector that combines rapid response with high measurement accuracy. Its built-in sampling pump ensures a fast flow rate and a response time of ≤20 seconds, giving you real-time readings when you need them most. The housing is made of high-strength engineering plastic – rugged yet lightweight, with dimensions of only 205×75×32mm and a net weight of 300g. This makes it easy to carry for daily patrols, leak checks, and emergency site surveys across diverse industrial environments.

Core Advantages
  • Active pumping system – delivers fast sample extraction, ensuring ≤20s response for timely detection.
  • High precision – accuracy ≤±1–5% F.S., repeatability ≤±1%, and zero drift ≤±1% F.S./year for consistent, trustworthy data.
  • Explosion-proof certified – rated Ex ia IIC T4 Ga, safe for use in hazardous zones.
  • Triple alarm – sound, light, and vibration alerts ensure you never miss a warning, even in noisy conditions.
  • Optional data logging – stores up to 100,000 readings; data can be exported to PC via USB for analysis.
  • One-key restore – quickly reset to factory settings, simplifying maintenance and operation.
Product Pictures

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

SKY2000 Pump-Suction Combustible Gas Detector with 0–100%LEL Range 1%LEL Resolution and Data Logging USB Export

Technical Specifications
Parameter Specification
Gas Detected EX (Combustible / LEL)
Detection Principle Catalytic combustion
Measuring Range 0 – 100% LEL
Resolution 1% LEL
Precision ≤ ±1–5% F.S. (for special gases may vary)
Data Logging (Optional) 100,000 readings storage, export via USB to PC software
Response Time ≤ 20 seconds
Repeatability ≤ ±1%
Zero Shift ≤ ±1% F.S./year
Operating Language Chinese / English switchable
Temperature Range -20℃ – 50℃
Explosion-Proof Rating Ex ia IIC T4 Ga
Alarm Mode Sound, light, and vibration (triple alarm)
Dimensions 205 × 75 × 32 mm
Recovery Time ≤ 10 seconds
Linearity Error ≤ ±1%
Display LCD dot-matrix display with backlight
Gas Unit Switchable units
Humidity Range 0 – 95% RH
Degree of Protection IP66
Operating Time 100 hours (with pump off)
Weight 300g

The same detector also supports CO, H₂S, O₂ and other gases with different ranges and resolutions. For EX, the range is 0–100% LEL and resolution is 1% LEL as shown above.

Product Features – Designed for Real-World Use
  • LCD dot-matrix display with backlight – clear readings even in dim environments.
  • Bilingual interface – switch between Chinese and English to suit local operators.
  • Switchable gas units – adapt to different regional measurement habits.
  • Wide operating temperature – works reliably from -20℃ to 50℃.
  • High protection class – IP66 rated, dust-tight and water-resistant for harsh conditions.
  • Long battery life – up to 100 hours of continuous operation (with pump off), reducing charging downtime.
Typical Applications

The SKY2000 is widely used in petrochemical plants, natural gas pipelines, coal mines, metallurgy, municipal gas networks, fire emergency response, environmental monitoring, and confined-space entry. Whether for routine safety patrols, pinpointing leaks, or emergency incident response, this detector provides accurate combustible gas concentration data and reliable early warning protection to keep your team and site safe.

About the Manufacturer

Shenzhen YuanTe Technology Co., Ltd. (Safegas) – founded in 2010, with over 16 years of experience in R&D, manufacturing, and sales of gas detection equipment and integrated systems. The company serves oil & gas, chemicals, energy, environmental protection, electronics, municipal engineering, agriculture, and home appliances.

Key credentials:
  • ISO9001 and ISO45001 certified
  • IECEx, ATEX, and EMC certifications
  • Annual production capacity: >80,000 units
  • Global distribution network with 24/7 customer support
  • Product portfolio includes portable gas detectors, fixed transmitters, control panels, calibration accessories, and custom solutions.

Contact Details
Nancy Lee

Phone Number : +8613072743898

WhatsApp : +8613072743898