Basic Information
Place of Origin: China
Brand Name: Safegas
Certification: ATEX/IECEx
Model Number: SG100-S
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Carton
Delivery Time: 3 Working days
Payment Terms: T/T
Supply Ability: 100 Pieces/day
Detail Information
Target Gas: Oxygen (O2) Detection Principle: Electrochemical Sensor
Measuring Range: 0-30%VOL Resolution: 0.1%VOL
Protection Class: IP66 / IP68 Accuracy: ≤±2-5%FS
Working Voltage: 12-24VDC Power Dissipation: <2.5W
Dimension: 157.8×128.8×69.6mm Weight: 1.0 Kg
Highlight:

Wall-mounted Oxygen Monitor

,

Plug-and-Play Sensor Oxygen Detector

,

Splash-Guard Oxygen Monitor


Product Description

Product Overview

The SG100-S is a cost-effective, IECEx & ATEX-certified explosion-proof fixed online gas transmitter designed for continuous oxygen (O2) monitoring. Housed in S316 stainless steel, it uses an electrochemical sensor with a measuring range of 0–30%VOL and a resolution of 0.1%VOL.

Featuring IP66/IP68 ingress protection, an intelligent plug-and-play sensor module, multiple standard signal outputs, and optional wireless transmission, the unit also supports magnetic remote control. It simplifies field installation and routine maintenance while delivering reliable 24-hour continuous oxygen-concentration monitoring for confined-space access, underground tunnels, sewage chambers, and industrial production facilities.

Understanding Oxygen (O2) Monitoring

Oxygen is essential for human survival. Insufficient oxygen concentration can cause hypoxia, dizziness, and loss of consciousness, while excessive oxygen may also introduce safety risks in certain industrial environments. Confined spaces, underground pipelines, and enclosed tanks are prone to oxygen-content deviation caused by gas consumption or displacement. Continuous fixed-point oxygen monitoring is therefore critical to safeguarding on-site operators entering these hazardous zones.

Product Pictures
Key Technical Specifications
Parameter Value
ModelSG100-S
Target GasOxygen (O2)
Detection PrincipleElectrochemical sensor
Measuring Range0–30%VOL
Resolution0.1%VOL
Accuracy≤±2–5%FS (sensor-dependent)
Explosion-proof GradeIECEx / ATEX: Ex db IIC T6 Gb, Ex db ia IIC T6 Gb
Protection ClassIP66 / IP68
Power DissipationToxic gas < 2.5W
Working Voltage12–24VDC
Communication4–20mA (2-wire / 3-wire), RS485 Modbus; HART optional
Wireless OptionLoRa, 4G (optional)
Relay3 relays (low / high / fault alarm, optional)
DisplayLED digital display
Working Temperature-20℃ ~ 50℃
Working Air Pressure86kPa ~ 106kPa
Housing MaterialS316 stainless steel; die-cast aluminum optional
Cable Entry1 * ¾ NPT & 1 * M20
Dimension157.8 * 128.8 * 69.6mm
Weight1.0 Kg
Standard AccessorySplash guard, mounting bracket
Warranty1 year
Main Features
  • Intelligent plug-and-play sensor module: Supports calibration via Safegas PC software. When the sensor reaches end-of-life, users only replace the sensor module on-site — no need to send the whole unit back to the factory, greatly reducing maintenance workload and equipment downtime.
  • IP66/IP68 high-grade dust- and water-resistant enclosure with standard splash guard: The splash guard effectively blocks splashing water, rain, and large-particle dust. It adapts to outdoor installations and damp workshop environments, protecting the internal sensor core from environmental erosion.
  • Multiple compatible signal output options: Supports 2-wire / 3-wire 4–20mA and RS485 Modbus, with optional HART output. It connects seamlessly to mainstream PLC, DCS, and various industrial control systems for centralized data acquisition.
  • Optional LoRa and 4G wireless transmission modules: Enables remote real-time data viewing and historical-data downloading. Users can grasp oxygen-concentration status remotely without on-site inspection.
  • Optional 3-relay group for alarm linkage: Low-alarm, high-alarm, and fault-alarm relay outputs can drive external alarm lamps, buzzers, and ventilation-interlock equipment, automatically triggering safety actions once oxygen concentration deviates from safe thresholds.
  • Magnetic non-contact operation: Parameter setting, zero adjustment, and other configurations can be completed with a magnetic tool without opening the instrument housing, ensuring safe operation within explosive-hazard areas.
  • Complete mounting-bracket accessories supplied: The ready-to-use bracket simplifies wall-mount installation and shortens on-site construction time for engineering projects.
  • Dual-material housing selection: Standard S316 stainless-steel housing, with die-cast aluminum housing as an alternative, coping with ordinary and moderately corrosive industrial atmosphere scenarios respectively.
Typical Applications
  • Confined-space pre-entry oxygen-safety continuous monitoring
  • Underground tunnel and pipeline work-area oxygen detection
  • Sewage-chamber and manhole-peripheral gas supervision
  • Chemical-industry enclosed-tank maintenance-site safety warning
  • Mining-site underground working-area oxygen monitoring
Frequently Asked Questions

Q1: What gas is this SG100-S configured for?

This unit is customized for oxygen (O2). Sensors for other toxic, combustible, and VOC gases are available for selection.

Q2: What range and resolution are available for O2?

Measuring range: 0–30%VOL; resolution: 0.1%VOL.

Q3: What signal outputs does the transmitter provide?

2-wire / 3-wire 4–20mA and RS485 Modbus as standard; HART, LoRa, and 4G are optional.

Q4: What are its explosion-proof and ingress-protection ratings?

Explosion-proof: Ex db IIC T6 Gb / Ex db ia IIC T6 Gb; IP66/IP68 dust- and water-resistant.

Q5: How is sensor maintenance performed on-site?

It adopts a plug-and-play sensor module; calibration can be completed with Safegas PC software.

Q6: Does it support a relay-alarm-output function?

A three-relay assembly for low-alarm, high-alarm, and fault-alarm is optional.

Q7: What are the power-supply requirements?

Working voltage 12–24VDC; power consumption less than 2.5W for the oxygen-sensor configuration.

Q8: What housing-material options are there?

Standard S316 stainless-steel housing; die-cast aluminum housing is optional.

Q9: Can it be deployed in wet or splash-prone locations?

Yes, a standard splash-guard accessory is included.

Company Introduction & Advantages

Shenzhen YuanTe Technology Co., Ltd. (Safegas) — Established in 2010, YuanTe specializes in the R&D, manufacturing, and sales of gas detection equipment and integrated systems, with over 16 years of experience. The company serves industries including oil & gas, chemicals, energy, environmental protection, electronics, municipal engineering, agriculture, forestry, and household appliances.

Key Advantages
  • International certifications: IECEx, ATEX, and EMC certified for explosive atmospheres.
  • Full product range: Portable detectors, fixed transmitters, analyzers, control panels, docking stations, and accessories.
  • Wide gas coverage: Hundreds of gases (toxic, flammable, oxygen, VOCs, CO2, refrigerants, etc.).
  • Quality management: ISO9001 and ISO45001 certified; over 100 independent intellectual property patents.
  • High production capacity: Over 80,000 units per year; fast delivery (typically 5–7 working days).
  • Global support: 24/7 after-sales service and tailored solutions.

Contact Details
Nancy Lee

Phone Number : +8613072743898

WhatsApp : +8613072743898