Application: | Factory Aseptic Workshop Operating Room Sickroom | Test Gas: | O3, Ozone |
---|---|---|---|
Product Name: | Disinfection Gas Detector | Sampling Type: | Pump And Diffusion |
Color: | Black | Certificate: | IECEx |
Highlight: | CNEX Portable Toxic Gas Detector,ISO 9001 Toxic Gas Detector,CNEX Ozone Gas Detector |
O3 Ozone Gas Detector Disinfection Gas Detector For Factory Aseptic Workshop Operating Room Sickroom
SKY3000 series is a high-performance portable gas detector that can detect multiple gases (Oxygen compounds VOC, combustible gas and toxic gas) at the same time and has man down alarm function. The device has humanized operation functions such as one-key security detection, one key storage, automatic image flipping, as well as the man down alarm function; With optionalBluetooth transmission function, allowing safety personnel to obtain real-time data and the alarm status. It has obtained international IECEX, ATEX explosion-proof certification and Chinese explosion-proof certification; As it passed the antistatic test, and the protection level reaches IP67; With safer product design and the module designwhich makes the detection faster, and the compact ergonomic designmakes the device easy carrying; What’s more, the device is also a suction and diffusion dual-purpose instrument. The instrument is mainly working in suction mode. When the air pump fails or in special emergency situations, it can automatically switch to the diffusion sampling method, thereby improving the protection to a new Level.
Yuante portable multi gas detector adopt advanced gas sensor and micro control technical, has quick response, high accuracy, great stability and repeatability, it's easy to operate, performance is in the leading level of gas detection industry.
Ozone Gas Detector specifications
Gas type | Disinfection Gas |
Measure range | O3, Ozone |
Resolution | 0-20ppm |
Response time | ≤30 seconds |
Precsiion | ≤±2%F.S |
Automatically test and calibrate after power-on | Including reset, maximum value (MAX), minimum value (MIN), STEL, TWA value |
Unit | PPM and mg/m³ can be switched |
Data record | Can store 100,000 sets data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported |
Alarm | 95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm status indication on the screen, alarm latched; diagnostic alarm and battery undervoltage alarm, pump block alarm; man down alarm, with early warning and optional real-time remote Bluetooth notification function |
Battery | 3.7V rechargeable lithium battery, battery capacity 2200mA |
Working hours | More than 15 hours in continuous pumping mode |
Charger | Travel charger with DC interface, charging time ≥ 4 hours |
Explosion-proof grade | IECEX/ATEX(II IG Ex ia IIC T4 CNEX:Ex ia IIC T4 Ga |
Certification (EU regulations) |
2004/108/EC(EMC) 1995/5/EC(Radio) 94/9/EC(ATEX) |
Protection grade | IP67 |
Working temperature | -20ºC~+50ºC |
Humidity | 0~90%RH(no condensation) |
Environmental pressure | 86~106Kpa |
1. Astigmatic design is applied to rugged surroundings;
2. Continuously gas concentration and composition colorful LCD real-time display;
3. Rechargeable lithium battery (continuous working period can be 16~18 hours);
4. Concentration units ppm and mg/m3 can be switched
5. Built-in vibration alarm which is applied for noisy environment;
6. Two stage alarm threshold: the low alarm and high alarm point can be adjusted based on actual needs;
7. Simple automatic calibration program and plug-in replaceable sensor;
8. Fully functional self-testing: sensor, integrity of battery and circuit, acoustic & visual & vibration three-stage alarm;
9. Small figure and light weight;
10. Password protection capability: only the authorized user can modify the preset parameter.
Precautions
1. It is strictly forbidden to use in a high temperature and high pressure environment. If the humidity of the environment is high, a filter and dehumidification device must be installed
2. The user is not allowed to repair or replace parts without authorization
3. Man-made damage is not covered by the warranty
4. It is not allowed to change the components or structures that affect the explosion-proof performance at will, so as not to affect the explosion-proof performance
5. The battery must be replaced with the same type of battery and carried out in a safe place