Send Message
products

Monitoring PID VOC Sensor 10.6eV 11.7eV IECEX ATEX Fix Wall Mount VOC Gas Detector

Basic Information
Place of Origin: China
Brand Name: YuanTe
Certification: SIL CE ATEX IECEX ISO9001-2015
Model Number: YT-98H
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Carton Box
Delivery Time: 2-3 days
Payment Terms: T/T, Western Union, Credit Card
Supply Ability: 500PCS/DAY
Detail Information
Detected Gas: VOC, TVOC, VOCs, TVOCs Measure Range: 0-1ppm, 0-3ppm, 0-10ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-10000ppm
Sampling Method: Built In Pump Detection Principle: PID 10.6eV 11.7eV
Install Method: Wall Mounted&Pipe&Flow-type&Confined Space Display: Color Display
Power Supply: 12-24VDC Signal Output: 4-20mA&RS485
Material: Die-cast Aluminum Case, Stainless Steel Air Chamber Explosion Proof Construction: Ex D IIC T6 Gb, IP67
High Light:

IECEX PID VOC Sensor

,

PID Monitoring VOC Gas Detector

,

Wall Mount VOC Gas Detector


Product Description

 

PID VOC Sensor Monitoring 10.6eV 11.7eV IECEX ATEX Fix Wall Mount VOC Sensor VOC Gas Sensor

 

YT-98H-WH / YT-98H-WH-A series is a built-in pump-suction single & multi gas detector, which can detect 1-6 kinds of gases simultaneously and continously. With IECEx, ATEX certificate (on-going) and non-contact magnetic wand design, it can be installed and operated in explosion proof areas in Oil & Gas industry. In addition to 3-wire 4-20mA output with relay, it also offers Modbus protocols, making it compatible with most control systems. With optional wireless function, operator can view data on laptop, mobile phone or cloud system remotely.

 

PID VOC Sensor Monitoring advantage:

 

  • With internal suction pump, fast response
  • Up to 6 kinds of gases can be detected at the same time. In complex and multi-gas environments, multiple installations can be reduced, saving time and effort.
  • 2.4-inch industrial-grade high-definition color screen with a resolution of 320*240 and a wide viewing angle of 120 degrees.
  • With wireless module, data can be uploaded to the cloud platform, environmental protection bureau or other
  • Platforms, providing SMS reminder function, the transmission signal is not limited by distance, and can be viewed in real time on mobile phones and computers. (optional)
  • With full software automatic verification function and zero calibration function, making gas monitoring more accurate and more reliable.
  • Standard 4-20mA current signal, RS485 modbus signal, 1 set of relay signal output
  • Standard infrared remote control, which can remotely control the detector and modify the detector settings.
  • With sound and light alarm function, there is sound and light alarm when reaching the alarm point. (optional)

 

 

PID VOC Sensor Monitoring Specification

 

Sampling method Built in pump
Pump flow rate 0.35-0.5 L/Min

Gas detected

VOC, Oxygen(O2), Combustible gases(EX/LEL), Carbon monoxide(CO), Hydrogen sulfide(H2S), according to customer's requirements

Detection principle

PID 10.6eV, 11.7eV, Catalytic combustion/Infrared Ray(LEL), Electrochemistry(O2 CO H2S), sensor and ic are imported from UK, fast response and high precision

Install method

Wall-mounted, piping type, flow-type (according to the detected environment)

Measure range

VOC: 0-1ppm, 0-3ppm, 0-10ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-10000ppm; O2: 0-30%VOL/0-25%VOL, EX: 0-100%LEL/0-100%VOL, CO: 0-500ppm/0-1000PPM/0-2000ppm, H2S: 0-100ppm/0-200PPM(Measure range is optional)

Resolution

VOC: 0.001ppm, 0.01ppm, 0.1ppm, 1ppm; O2: 0.01%VOL, EX: 1%LEL/0.01%VOL, CO: 0.1ppm/1PPM/1ppm, H2S: 0.01ppm/0.1PPM

Precision

≤± 2% FS

Signal output

4-20mA, RS485, 1 set of relay output; 1-5VDC(optional), 2 sets of relay output(optional)

Response time

≤10S

Recovery time

≤10S

Repeatability

≤±1%

Linearity error

≤±1%

Zero shift

≤±1%(FS/year)

Display

High-light nixie tube display

Connection mode

G1/2 external thread explosion-proof flexible pipe

Unit

ppm, mg/m3, g/m3, %LEL, %VOL

Temperature

-20 to 50°C

Humidity

0-95%RH

Explosion-proof

Ex d IIC T6 Gb

Degree of protection

IP65

Alarm

Sound, light

Operating time

24H

Dimensions

286*202*96mm (H x W x D)

Weight

3.4kg (3.8kg with alarm light)

 

Monitoring PID VOC Sensor 10.6eV 11.7eV IECEX ATEX Fix Wall Mount VOC Gas Detector 0

 

Monitoring PID VOC Sensor 10.6eV 11.7eV IECEX ATEX Fix Wall Mount VOC Gas Detector 1

 

Applications for PID VOC Sensor Monitoring

 

Biogas factory, Garbage station, Wastewater treatment, Air quality, Chemical industry, food factory, software engineering, environmental protection, animal husbandry, mining, power engineering, etc.

Furniture, Floor, Wallpaper, Coating, Gardening, Interior Decoration and Renovation, Dyestuff, Papermaking, Pharmacy, Health Care, Foodstuff, Antiseptic.
Disinfection, Chemical Fertilizer, Resin, Adhesive, Pesticide, Raw Material, Sample, Technological Process,
Livestock Farm, Refuse Processing Plant, Perm Place.
Bio-pharmaceutical Plant, Green Household, Livestock Breeding, Green House Cultivating, Warehouse Logistics, Brewing And Fermentation, Agricultural Production.

At present, we have cooperated with Coca-Cola Company, Nestle, State Grid Administration, Samsung, HuaWei, etc.

 

Monitoring PID VOC Sensor 10.6eV 11.7eV IECEX ATEX Fix Wall Mount VOC Gas Detector 2

 

 

Contact information:


 

Celia Wu

SHENZHEN YUANTE TECHNOLOGY CO.,LTD(Safegas)

Mobile/WhatsApp/Wechat: +86 15889417475

Skype: celia.wu888

Email: sales04@szyuante.com

 

Contact Details
Celia Wu

Phone Number : 0086 15889417475

WhatsApp : +8615889417475