| Gas Detected: | O2, N2, CO2, EX, Hazardous Gas, Voc, Etc | Detection Principle: | Electrochemical, Infrared Ray, Catalytic Combustion, PID Photo Ionization, Etc |
|---|---|---|---|
| Power: | 12-24V DC | Accuracy: | ≤±2-5%FS (depending On The Specific Sensor) |
| Response Time(T90): | 15-30s(depending On The Specific Sensor) | Repeatability: | ≤±1% |
| Pump Flow: | 0.35-0.5 L/Min | Temperature: | –20℃~55℃ |
| Humidity: | 0-95%RH(no Condensation) | Alarm(Optional): | Buzzer, Alarm Status Prompt On The Display Screen, High And Low Alarm Values Can Be Set By Customer |
| Highlight: | Multi Gas Detector with Pump,Industrial Use Multi Gas Detector,Fixed Multi-Gas Detector |
||
YT-98H/YT-98H-A Fixed Gas Detector is a built-in pump-suction single & multi gas detector with IECEx and ATEX certification. Featuring non-contact magnetic wand design, it can be installed and operated in explosion-proof areas and Oil & Gas industries. The detector offers 3-wire 4 to 20-mA output with relays, HART, and Modbus protocols for compatibility with most control systems. Optional wireless function allows operators to view data remotely on laptops, mobile phones, or cloud systems.
| Parameter | Specification |
|---|---|
| Gas Detected | O2, N2, CO2, EX, hazardous gas, VOC, etc |
| Detection Principle | Electrochemical, infrared ray, catalytic combustion, PID photo ionization |
| Installation Method | Wall-mounted, piping type, flow-type |
| Accuracy | ≤±2-5%FS (depending on specific sensor) |
| Signal Output | 4-20mA, RS485, relay |
| Response Time (T90) | 15-30s (depending on specific sensor) |
| Display | 2.4-inch color display, resolution 320*240 |
| Operating Temperature | -20ºC to 55ºC |
| Humidity | 0-95%RH |
| Explosion-Proof | IECEX: Ex db IIC T6 Gb | ATEX: Ex db IIC T6 Gb |
| Protection Level | IP66 |
| Dimensions | 43×27×15cm |
| Weight | 4.6kg |