logo
products

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor

Basic Information
Place of Origin: China
Brand Name: safegas
Certification: ATEX/IECEX
Model Number: YT98-H
Minimum Order Quantity: 1 piece
Price: 620USD
Delivery Time: 3-5days
Payment Terms: T/T
Supply Ability: 8000 pcs per month
Detail Information
Measure Range: 0-500PPM/0-1000PPM/0-10000OPPM Gas: Customized
Sensor Type: Specified According To Application Language: Chinese/English
Alarm Type: Light+Sound+Vibration Detection Principle: Pumping Electrochemical, NDIR, Catalytic, PID, Etc
Weight: 3.4kg (3.8kg With Alarm Light) Size: 286*202*96mm (H X W X D)
Sampling: Built In Pump Display: High-light Nixie Tube Display
Highlight:

RS485 Output NH3 Gas Detector

,

Pumping Electrochemical Sensor NH3 Gas Detector

,

Durable Fixed NH3 Gas Detector


Product Description

Product video
 
Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 0


 

Our advantages

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 1

Product description

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 2Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 3Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 4Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 5Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 6Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 7

The YT-98H-D/YT-98H-D-A series is a fixed gas detector that excels in performance. It can simultaneously and continuously monitor 1 - 6 gas types. Holding IECEx and ATEX certifications, along with its non-contact magnetic wand design, it is perfectly suited for hazardous area installation and operation. The detector offers multiple signal output options like 3-wire 4 - 20mA, RS485 Modbus, relay, and an optional Hart signal, ensuring seamless integration with various control systems. With the added benefit of optional wireless data transmission, users can effortlessly access real-time data on their laptops or mobile phones remotely. This product combines reliability, safety, and advanced technology to meet the stringent demands of gas detection in diverse industries.

 

Product advantage

 

  • Up to 6 kinds ofgases can be detected simultaneously.In complex and multi-gas environments, it is able to saving installation time and effort
  • With wireless communicate function, uploading data to cloud platform so user is able to check and download data remotely.There is also SMSand E-mail alarm alert function in real time.(optional)
  • With manually span and zero calibration function,making gas monitoring more accurate and more reliable.
  • Standard 4-20mA analog signal, RS485 modbus signal and relay signal output, optional HART output.
  • Standard infrared remote control,optional non-contact magnetic wand control.
  • With sound and light alarm function, there is sound and light alarm when reaching the alarm point.(optional)
  • With fault alarm, will send alarm when sensor disconnect.
  • IP66 protection grade, water proof and dust proof

 

 

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 8Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 9Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 10Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 11Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 12Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 13

company profile

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 14Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 15Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 16Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 17Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 18Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 19Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 20

certifications

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 21

FAQ

Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 22Durable Fixed NH3 Gas Detector with 4-20mA RS485 Output and Pumping Electrochemical Sensor 23

specification

Sampling method Built in pump
Pump flow rate 0.35-0.5 L/Min
Gas detected Ozone(O3),VOC, Oxygen(O2), Combustible gases(EX/LEL), Carbon monoxide(CO), Hydrogen sulfide(H2S), according to customer's
requirements
Measure Range Specified according to application
Resolution O3: 0.01ppm, 0.1ppm
VOC: 0.001ppm, 0.01ppm, 0.1ppm, 1ppm
O2: 0.01%VOL
EX: 1%LEL/0.01%VOL
CO: 0.1ppm/1PPM/1ppm
H2S: 0.01ppm/0.1PPM
Response time(T90):
≤10 seconds
Signal output 4-20mA, RS485, 1 set of relay output; 1-5VDC(optional), 2 sets of relay output(optional)
Display:
High-light nixie tube display
Zero shift
≤±1%(FS/year)
Connection mode
G1/2 external thread explosion-proof flexible pipe
Operating time 24H
Size 286*202*96mm (H x W x D)
Weight 3.4kg (3.8kg with alarm light)
Protection grade:

IP65

Contact Details
Mia Hu

Phone Number : +8613072743898

WhatsApp : +8613072743898