| Place of Origin: | China |
|---|---|
| Brand Name: | Safegas |
| Certification: | EX/ATEX |
| Model Number: | SKY2000 |
| Document: | SKY2000 Datasheet.pdf |
| Minimum Order Quantity: | 1 |
| Price: | Negotiable |
| Packaging Details: | Carton |
| Delivery Time: | 3 working days |
| Payment Terms: | T/T |
| Supply Ability: | 100 pieces/day |
| Gas Type: | Nitrogen (N2) | Detection Range: | 0-100%VOL |
|---|---|---|---|
| Detection Principle: | Electrochemical (oxygen Cell With Reverse Calculation) | Suction Method: | Pump Suction |
| Package Type: | Aluminium Suitcase | Portability: | Portable |
| Recovery Time: | ≤10 Seconds | Display: | LCD Dot Matrix With Backlight |
| Alarm Mode: | Sound, Light, Vibration |
A fast-response, high-accuracy handheld gas detector with built-in sampling pump for nitrogen (N₂) monitoring. Measures from 0–100%VOL with 0.1%VOL resolution using an electrochemical sensor. Features Ex ia IIC T4 Ga explosion-proof certification, IP66 protection, 100 hours runtime (pump off), and triple alarm (sound, light, vibration). Optional data logging (100,000 readings) via USB. Ideal for confined space safety, inert gas monitoring, and industrial hygiene.
The SKY2000 series is a portable, pump-suction gas detector designed for fast response and high accuracy. With an internal sampling pump, it actively draws air for immediate analysis – ideal for spot checks and confined space entry.
Taking nitrogen (N₂) as an example – a common inert gas used for purging and blanketing – the SKY2000 measures nitrogen concentration from 0–100%VOL with 0.1%VOL resolution. The detector supports span calibration and zero calibration for reliable readings, plus a one-key factory reset. Optional data logging (up to 100,000 readings) can be exported to PC via USB without additional software.
The device provides sound, light, and vibration alarms, an LCD dot matrix display with backlight, and switchable gas units (ppm, mg/m³, %VOL, %LEL). Its high-intensity engineering plastics housing is both durable and lightweight (300g).
Nitrogen (N₂) makes up about 78% of the air we breathe. It is colorless, odorless, and non flammable. While not toxic, nitrogen acts as a simple asphyxiant – it can displace oxygen in confined spaces, leading to rapid unconsciousness and death if oxygen levels fall below 19.5% VOL. Common sources of nitrogen hazard include inert gas purging, cryogenic nitrogen storage, chemical blanketing, and laboratory glove boxes. Monitoring nitrogen levels indirectly via oxygen depletion is critical for worker safety. The SKY2000 helps detect oxygen displacement (inverse of N₂) to prevent asphyxiation.
| Parameter | Value |
|---|---|
| Gas Detected | Nitrogen (N₂) – also supports CO, H₂S, O₂, LEL, and hundreds of other gases |
| Detection Principle | Electrochemical (oxygen cell with reverse calculation) |
| Measuring Range | 0 – 100%VOL |
| Resolution | 0.1%VOL |
| Precision | ≤ ±1–5% FS |
| Response Time (T90) | ≤20 seconds |
| Repeatability | ≤ ±1% |
| Zero Shift | ≤ ±1% (FS/year) |
| Linearity Error | ≤ ±1% |
| Recovery Time | ≤10 seconds |
| Display | LCD dot matrix with backlight |
| Gas Unit | Switchable (ppm, mg/m³, %VOL, %LEL) |
| Data Logging | Optional: 100,000 readings, export via USB |
| Sampling Method | Built-in pump (active suction) |
| Alarm Mode | Sound, light, vibration |
| Explosion-Proof Grade | Ex ia IIC T4 Ga |
| Protection Grade | IP66 |
| Operating Temperature | -20°C to +50°C |
| Operating Humidity | 0–95% RH |
| Operating Time | 100 hours (pump off) |
| Dimensions | 205 × 75 × 32 mm |
| Weight | 300 g |
Shenzhen YuanTe Technology Co., Ltd. (brand: Safegas) was established in 2010 and specializes in the R&D, manufacturing, and sales of gas detection equipment and integrated systems. With over 16 years of industry expertise, the company serves sectors including oil & gas, chemicals, environmental protection, electronics, municipal engineering, agriculture, and household appliances. All products are manufactured under ISO9001 and ISO45001 management systems, holding international certifications such as IECEx, ATEX, and EMC. With an annual production capacity of over 80,000 units, YuanTe Technology supplies gas detection solutions to customers worldwide.
Q1: What gas does this detector measure?
A: It measures Nitrogen (N₂).
Q2: What is the measuring range and resolution?
A: Range 0–100%VOL, resolution 0.1%VOL.
Q3: Does it have a built-in pump?
A: Yes, built-in sampling pump for active suction detection.
Q4: What is the response time?
A: ≤20 seconds, fast and sensitive.
Q5: Does it support data recording?
A: Optional data logging stores 100,000 readings and supports USB export.
Q6: What alarm methods are provided?
A: Sound + light + vibration triple alarm.
Q7: Is it explosion-proof?
A: Yes, Ex ia IIC T4 Ga certified.
Q8: What is the protection grade?
A: IP66 waterproof and dustproof.
Q9: How long can it work continuously?
A: Up to 100 hours when the pump is off.
Q10: What are the dimensions and weight?
A: 205×75×32 mm, weight 300 g.