logo
products

YT-98H Fixed Multi-Gas Detector with 4-in-1 CO/H₂S/O₂/LEL Monitoring Built-in Vacuum Pump and Imported Sensors

Basic Information
Place of Origin: China
Brand Name: Safegas
Certification: ATEX/IECEx
Model Number: YT-98H
Document: YT-98H Datasheet.pdf
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Carton
Delivery Time: 5 working days
Payment Terms: T/T
Supply Ability: 100 pieces/day
Detail Information
Gases Detected: CO, H₂S, O₂, LEL (up To 6 Gases Total – Additional Gases Selectable) Detection Principles: Electrochemical (CO/H₂S/O₂), Catalytic Combustion (LEL)
Resolution: CO 1PPM, H2S 0.1PPM, O2 0.1%VOL, LEL 1%LEL Accuracy: ≤ ±2% FS (depending On Specific Sensor)
Response Time (T90): ≤20 Seconds (depending On Specific Sensor) Pump Flow Rate: 0.5 L/min
Pump Operating Life: >12,000 Hours Continuous Display: 2.4-inch Color LCD, 320×240 Resolution

Product Description

YT-98H Fixed Multi-Gas Detector with 4-in-1 CO/H₂S/O₂/LEL Monitoring Built-in Vacuum Pump and Imported Sensors
Product Overview

The YT-98H series is a fixed multi-gas detector designed for continuous, simultaneous monitoring of up to six gases. In its standard four-gas configuration, it tracks CO (0-1000ppm, 1ppm), H₂S (0-100ppm, 0.1ppm), O₂ (0-30%VOL, 0.1%VOL), and LEL (0-100%LEL, 1%LEL) using electrochemical cells for the first three and catalytic bead sensing for combustibles.

Central to its design is an internal vacuum pump that actively draws sample air at 0.5 L/min, with a continuous service life exceeding 12,000 hours. This active extraction delivers T90 response within 20 seconds and allows the detector to be placed in safe, accessible areas while sampling from ducts, vessels, or confined spaces - reducing the need for personnel to enter hazardous zones for routine checks.

The unit provides standard 3-wire 4-20mA, RS485 Modbus, and one relay output, with optional second relay, HART, or voltage signals (0-10V, 0-5V, 1-5V) for flexible integration with control systems. Configuration is performed without opening the enclosure, using the supplied infrared remote control or an optional magnetic wand - preserving the flameproof seal in explosive atmospheres.

Product Images
Technical Specifications
Parameter Value
Gases detected CO, H₂S, O₂, LEL (expandable to 6 gases)
Detection principles Electrochemical (CO/H₂S/O₂), Catalytic combustion (LEL)
Measuring ranges CO: 0-1000ppm; H₂S: 0-100ppm; O₂: 0-30%VOL; LEL: 0-100%LEL
Resolution CO: 1ppm; H₂S: 0.1ppm; O₂: 0.1%VOL; LEL: 1%LEL
Accuracy ≤ ±2% FS (sensor-dependent)
Response time (T90) ≤20 seconds (sensor-dependent)
Repeatability ≤ ±1%
Pump flow rate 0.5 L/min
Pump continuous life >12,000 hours
Zero shift ≤ ±1% FS/year
Display 2.4-inch colour LCD, 320×240 resolution
Display content Gas formula, concentration, unit, pump status, alarm status
Languages Chinese, English
Alarm (optional) Sound/light (integrated or external); user-adjustable high/low setpoints
Fault alarm Sensor disconnect alert
Standard outputs 3-wire 4-20mA, RS485 Modbus, 1 relay
Configuration Infrared remote control (standard); magnetic wand (optional)
Operating temperature -10°C to +55°C
Humidity 0-95% RH (non-condensing)
Enclosure material Die-cast aluminium
Power supply 12-24V DC
Dimensions (H×W×D) 286 × 202 × 96 mm
Weight 3.4 kg (3.8 kg with alarm light)
Explosion-proof grade Ex d IIC T6 Gb
Protection grade IP65
Key Features
  • Built-in vacuum pump - Delivers a steady flow of 0.5 L/min with a continuous operating life exceeding 12,000 hours. Provides faster response (T90 ≤20s) and enables remote sampling from hard-to-reach areas.
  • Multi-gas capability - Monitors up to 6 gases simultaneously, reducing installation space and cost.
  • Non-intrusive configuration - Standard infrared remote control allows zero/span calibration, alarm setpoint adjustment, and parameter changes without opening the enclosure - preserving explosion-proof integrity in hazardous zones.
  • Rich display interface - 2.4-inch industrial-grade colour LCD with 320×240 resolution and 120-degree wide viewing angle. Shows gas formula, real-time concentration, pump status, alarm indicators, and max/min values.
  • Flexible output options - Standard 3-wire 4-20mA, RS485 Modbus, and one relay. Optional second relay, HART, and voltage outputs - compatible with PLC, DCS, and SCADA systems.
  • Rugged construction - Die-cast aluminium housing, IP65 rated, and certified Ex d IIC T6 Gb for Zone 1 and 2 hazardous areas.
Typical Applications
  • Confined space entry - Install the detector outside manholes, tanks, or vessels while sampling inside. Perform pre-entry gas checks and monitor continuously during worker occupancy.
  • Underground utilities - Sample from lift stations, vaults, and sewer lines to detect H₂S and methane before personnel enter.
  • Ductwork and HVAC systems - Mount the detector in a mechanical room and draw samples from air ducts to check for refrigerant leaks or combustion by-products.
  • Storage tanks and vessels - Sample headspace during cleaning, inspection, or maintenance to detect flammable or toxic residues.
  • Flue gas stacks - With the optional high-temperature pre-treatment system, sample flue gas up to 1200°C for combustion efficiency monitoring.
  • Oil and gas refineries - Sample from flare stacks, catalytic cracker enclosures, and amine treatment areas for H₂S and LEL.
  • Chemical plants - Monitor reactor vent lines and storage tank headspaces for toxic intermediates and flammable releases.
Optional Accessories
  • Sound/light alarm (integrated or external)
  • Water-vapour filter cartridge
  • Automatic dehumidification & drainage system (ambient temperature)
  • Manual dehumidification & drainage system (ambient temperature)
  • High-temperature flue gas pre-treatment system (up to 1200°C)
Frequently Asked Questions
Q1: How many gases can the YT-98H detect simultaneously?
A1: Up to 6 gases. The standard 4-in-1 configuration is CO, H₂S, O₂, and LEL.
Q2: What is the pump flow rate and how long does it last?
A2: Flow rate is 0.5 L/min; continuous operating life exceeds 12,000 hours.
Q3: Can I configure the detector without opening the enclosure?
A3: Yes, the standard infrared remote control allows full configuration without opening the cover.
Q4: What output signals are provided as standard?
A4: 3-wire 4-20mA, RS485 Modbus, and 1 relay. Optional: 2nd relay, HART, and voltage outputs.
Q5: What is the response time?
A5: T90 ≤20 seconds (sensor-dependent).
Q6: What is the protection rating?
A6: IP65 - dust-tight and protected against water jets.
Q7: Is it explosion-proof?
A7: Yes, certified Ex d IIC T6 Gb (IECEx and ATEX) - suitable for Zone 1 and 2 hazardous areas.
Q8: What is the operating temperature range?
A8: -10°C to +55°C.
Q9: Can it sample high-temperature flue gas?
A9: Yes, with the optional high-temperature pre-treatment system, sampling up to 1200°C is possible.
Q10: What is the warranty?
A10: 1 year for the detector.
Manufacturer Information

Shenzhen YuanTe Technology Co., Ltd. (brand: Safegas) was founded in 2010 and specializes in the research, development, manufacturing, and sales of gas detection equipment and integrated systems. With over 16 years of industry experience, the company serves sectors including oil and gas, chemicals, environmental protection, electronics, municipal engineering, agriculture, and household appliances.

All products are manufactured under ISO9001 and ISO45001 management systems and hold international certifications such as IECEx, ATEX, and EMC. With an annual production capacity exceeding 80,000 units, YuanTe Technology supplies gas detection solutions to customers worldwide, backed by a global distribution network and round-the-clock customer support.

Contact Details
Nancy Lee

Phone Number : +8613072743898

WhatsApp : +8613072743898