Basic Information
Place of Origin: China
Brand Name: Safegas
Certification: ATEX/EX
Model Number: SKY2000
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Carton
Delivery Time: 3 Working days
Payment Terms: T/T
Supply Ability: 100 Pieces/day
Detail Information
Ingress Protection: IP66 Target Gas: Nitrogen Oxides (NOX)
Detection Principle: Electrochemical Sensor Optional Measuring Ranges: 0-20ppm, 0-50ppm, 0-100ppm, 0-250ppm, 0-500ppm, 0-1000ppm, 0-2000ppm
Optional Resolution: 0.01ppm, 0.1ppm, 1ppm Precision: ≤±1-5% F.S
Response Time (T90): ≤20S Alarm Mode: Sound + Light + Vibration Triple Alarm
Highlight:

Multiple Measuring Ranges Nitrogen Oxides Detector

,

IP66 Multi Gas Detector

,

High Resolution Gas Analyzer


Product Description

Nitrogen Oxides Detector with Multiple Measuring Ranges & Resolutions, IP66
Professional-grade nitrogen oxides detector engineered for industrial applications. Features multiple measuring ranges and resolutions with IP66-rated housing for reliable operation in demanding environments.
Product Overview

SKY2000-NOX is pump-type NOX detector with electrochemical sensor, IP66 ingress protection and Ex ia IIC T4 Ga intrinsic safety standard. It supports multi-range & resolution selection, bilingual screen and optional data logging for flue gas inspection.

SKY2000 series gas detector is a kind of gas measuring equipment with high precision and quick response. The built-in sampling pump has fast sampling speed and large flow rate, which ensures the response time of the detector. Unique design, small size and convenient transportation. High-strength special engineering plastic shell is suitable for various occasions and environments. We are committed to providing you with the most reliable, accurate and safe gas detection solution.

SKY2000 detector is a gas measuring device with fast response speed and high precision. SKY2000 nitrogen detector is equipped with a built-in sampling pump, fast sampling speed, 10-level adjustable pump suction, high flow rate, up to 800ml/min, ensuring the response time of the detector.

Introduction to Nitrogen Oxides (NOX)

NOX is toxic exhaust generated by fuel combustion and chemical manufacturing. Long-term inhalation harms respiratory systems and triggers acid rain and smog. The built-in pump actively extracts flue gas to monitor concentration and meet environmental emission limits.

Product Pictures

Nitrogen Oxides Detector Multi Gas Analyzer with Multiple Measuring Ranges High Resolution and IP66 Protection

Nitrogen Oxides Detector Multi Gas Analyzer with Multiple Measuring Ranges High Resolution and IP66 Protection

Nitrogen Oxides Detector Multi Gas Analyzer with Multiple Measuring Ranges High Resolution and IP66 Protection

Nitrogen Oxides Detector Multi Gas Analyzer with Multiple Measuring Ranges High Resolution and IP66 Protection

Nitrogen Oxides Detector Multi Gas Analyzer with Multiple Measuring Ranges High Resolution and IP66 Protection

Nitrogen Oxides Detector Multi Gas Analyzer with Multiple Measuring Ranges High Resolution and IP66 Protection

Key Technical Specifications
Parameter Value
Model SKY2000
Target Gas Nitrogen Oxides (NOX)
Detection Principle Electrochemical sensor
Optional Measuring Ranges 0-20ppm, 0-50ppm, 0-100ppm, 0-250ppm, 0-500ppm, 0-1000ppm, 0-2000ppm
Optional Resolution 0.01ppm, 0.1ppm, 1ppm
Precision ≤±1-5% F.S
Response Time (T90) ≤20S
Recovery Time ≤10S
Repeatability ≤±1%
Annual Zero Shift ≤±1% F.S/year
Sampling Mode Built-in internal sampling pump
Display Backlit dot matrix LCD, Chinese & English switchable
Gas Unit One-key switchable multiple concentration units
Alarm Mode Sound + light + vibration triple alarm
Explosion Proof Grade Ex ia IIC T4 Ga
Protection Class IP66
Working Temperature -20℃ ~ 50℃
Working Humidity 0-95%RH (non-condensing)
Optional Data Logging Store 100,000 readings, export data via USB to PC software
Calibration Functions Zero calibration + span calibration
Factory Reset One press to restore factory parameters
Working Duration (pump closed) 100h
Dimension 2057532mm
Weight 300g
Main Features
  • Built-in high-flow sampling pump for fast gas extraction, T90 response within 20 seconds
  • Stable electrochemical NOX sensor, independent ranges and resolutions for different emission standards
  • IP66 heavy-duty plastic shell, dust and splash resistant for boiler and chemical workshops
  • Ex ia IIC T4 Ga intrinsic safety certification for flammable hazardous work zones
  • Backlit bilingual LCD, freely switch gas concentration units
  • Zero & span calibration reduces long-term measurement drift
  • One-key factory reset to quickly recover default parameters
  • Optional data logging module stores 100,000 groups of data for USB export
  • Triple sound-light-vibration alarm for clear warnings in noisy working sites
  • Low zero shift, stable repeatability and linearity for long-term continuous monitoring
  • Up to 100 hours continuous operation with pump off for all-day field patrol
Typical Applications
  • Power plant & boiler flue gas emission testing
  • Nitrogen fertilizer & chemical plant exhaust monitoring
  • Metallurgical smelting waste gas inspection
  • Automotive exhaust laboratory testing
  • Mobile environmental supervision sampling
  • Waste incinerator tail gas detection
Standard Package
  1. SKY2000 pumping gas detector ×1
  2. User manual ×1
  3. Certificate of conformity & warranty card ×1
  4. Charger ×1
  5. Premium aluminum alloy portable carrying case ×1
  6. Optional accessory: Data logging storage module
FAQ

Q1: What gas does SKY2000 detect?

A: This model is customized for nitrogen oxides (NOX). Other gas sensors are replaceable.

Q2: What ranges and resolutions are available for NOX?

A: Ranges:0-20/50/100/250/500/1000/2000ppm; Resolutions:0.01ppm,0.1ppm,1ppm.

Q3: Does it adopt active pumping sampling?

A: Yes, internal sampling pump draws flue gas automatically.

Q4: What are its protection and explosion-proof ratings?

A: IP66 dust & splash resistance, intrinsic safety grade Ex ia IIC T4 Ga.

Q5: Does it support calibration and factory reset?

A: Zero and span calibration available; one button restores factory settings.

Q6: Can test data be stored and exported?

A: Data logging is optional, saves 100,000 records and exports via USB.

Q7: How long can it work with the pump turned off?

A: Up to 100 hours of continuous operation.

Q8: What alarm types does it have?

A: Combined sound, light and vibration triple alarm.

Q9: Is the display bilingual?

A: Backlit LCD supports Chinese & English switching, gas units adjustable.

Company Introduction

Shenzhen YuanTe Technology Co., Ltd. operates under Safegas brand, founded in 2010 with over 16 years of gas detection R&D and manufacturing experience. We develop portable pumping detectors, fixed monitors and matching calibration equipment, all products comply with ISO9001 & ISO45001 standards and obtain IECEx, ATEX, EMC certifications. We provide full-set gas monitoring solutions for global industrial customers.

Company Advantages
  • 16+ years specialized experience in gas detection R&D and standardized production
  • Complete product line including portable pumping detectors, fixed monitors and matching calibration accessories
  • All core products pass IECEx, ATEX, EMC international explosion-proof certifications to meet global market access requirements
  • Customizable sensors for hundreds of toxic, flammable and exhaust gases
  • ISO9001 & ISO45001 certified production workshops with strict raw material inspection and finished product aging testing
  • Stable mass production capacity with standard 5–7 working day delivery cycle
  • 24-hour cross-border technical support, customized gas monitoring solutions for special industrial testing demands

Contact Details
Nancy Lee

Phone Number : +8613072743898

WhatsApp : +8613072743898